<LOGO>
FM Transmitter Measurement Report
Created: 2024-03-25 04-02-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 3/5, 37 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz 2.8 kHz -50 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
22 kHz 47 kHz 4821 0,0207
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
2,1 dBr 3,31 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 4:02, 25.03.2024
RT
"FRANCE INTER PREMIERE RADIO DE FRANCE "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F209, F222, F202, F206
FM Scope Station: 100.20 MHz, signal: 3/5 (37 dBuV) Max at: 47 kHz MIN: 22 kHz % above 75 kHz: 0,0207 Acquired: 2024/03/25 4:01:02 Total samples: 4821 Equivalent time: 0:04:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 4,1 dBr MIN: 2,1 dBr AVE: 3,31 dBr % above 10,2 dBr: 0,0 Last value: 2,4 dBr (2024/03/25 4:01:02) Station: 100.20 MHz, signal: 4/5 (37 dBuV) 03:48 03:50 03:52 03:54 03:56 03:58 04:00 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality